DRAFT FOR REVIEW — Not Doctor-approved for training. VERIFY items must be cleared before competency use.
Smile Avenue Family Dentistry
IN-HOUSE LABORATORY Cypress & Katy, TX
Document ID: SOP-LAB-110
Version 0.1 DRAFT  |  Target effective 09/10/2026

Models (study / thermoform)

SprintRay Die & Model 2 / Study Model White 2 — Lab Manufacturing Procedure

Smile Avenue Family Dentistry — In-House Laboratory
SprintRay Die & Model 2 and Study Model White 2 — Lab Manufacturing Procedure

Document ID SOP-LAB-110
Version 0.1 DRAFT
Effective (target) 09/10/2026
Owner Lab Technician (process owner)
Status DRAFT FOR REVIEW

Start: Case received in Medit Lab with scan QC
End: Model bagged and logged in SEAZONA for outbound delivery (or lab-hold for thermoform / wax-up use)


1. Purpose

This procedure standardizes in-house printing of SprintRay dental models (Die & Model 2 and Study Model White 2) for study, aligner/retainer thermoform masters, bleaching trays, and wax-ups.

2. Scope

In scope: Medit Lab intake → scan QC → model design/export (VERIFY path) → RayWare / Pro 2 → ProWash S → NanoCure → finish clean → bag & SEAZONA (or documented lab hold).

Out of scope: Patient-worn appliances printed on these resins (models are not definitive intraoral devices beyond IFU model uses); direct-print retainers (SOP-LAB-080); non-SprintRay printers.

3. Roles

Role Responsibility
Clinical Assistant / Office Sends case via Medit Lab; receives bagged model when outbound
Lab Technician Scan QC; design approve; print; wash; cure; clean; bag/hold; SEAZONA
Trainer / Lead Lab Technician Competency observation and sign-off
Doctor Indication / model purpose; remake authorization

4. Practice Configuration

# Item Smile Avenue setting
1 Printer Pro 2 only for this path
2 Resins Die & Model 2 or Study Model White 2 per Rx / purpose
3 Cure unit NanoCure — exact Die & Model 2 or Study Model White 2 profile
4 Case intake Medit Lab
5 Design VERIFY — outside CAD or SprintRay Cloud Design / model builder
6 Wash ProWash S — IPA ≥ 91% — standard preprogrammed cycle
7 Layer thickness Typically 100 µm default
8 Orientation Intaglio / anatomy facing away from platform (accuracy)
9 Design approval before print Lab Technician
10 Case log SEAZONA

5. Safety

6. Materials & Equipment

Resin Typical use
Die & Model 2 Dies, precision models, thermoform masters
Study Model White 2 Study / presentation / thermoform masters (white)

Equipment: Medit Lab → design (VERIFY) → RayWare → Pro 2 → ProWash S → NanoCure → SEAZONA.

7. Process Controls

Gate Do not proceed if Proceed when
Design Not approved / wrong resin for purpose QC-A pass
Printer Not Pro 2 Pro 2
Pre-cure Wet Fully dry
Cure Wrong profile Exact Die & Model 2 or Study Model White 2 complete
Outbound / hold Failed QC-E Bagged or documented lab-hold in SEAZONA

8. Procedure

A. Intake & scan QC

  1. Medit Lab: verify ID, arch(es), model purpose (study / thermoform / die / wax-up), resin choice, due date.
  2. QC-SCAN.

B. Design (VERIFY)

  1. Create/receive model STL; hollow/base settings per practice (VERIFY hollow defaults).
  2. Lab Technician approves. QC-A: Purpose match; resin noted; STL labeled.

C. Nest

  1. Model appliance type; Die & Model 2 or Study Model White 2; anatomy away from platform; ~100 µm; default supports; Pro 2.

D. Print

  1. Shake 1 minute; pour; assign shade/material; print; log lot. QC-B.

E. Wash & dry

  1. ProWash S standard cycle; dry fully. QC-C.

F. Post-cure

  1. NanoCure Die & Model 2 or Study Model White 2 exact profile. Remove supports. QC-D.

G. Finish, clean, bag / hold

  1. Soap + brush + warm water; dry.
  2. Bag for outbound or place in lab hold for thermoform workflow; log status in SEAZONA. QC-E.

End of SOP-LAB-110.

9. Case Log (SEAZONA)

Field Entry
Date / case ID
Purpose ☐ Study ☐ Thermoform ☐ Die ☐ Wax-up ☐ Other
Resin ☐ Die & Model 2 ☐ Study Model White 2 + lot
Design approved by (Lab Technician)
NanoCure profile Die & Model 2 ☐ / Study Model White 2 ☐
Disposition ☐ Bagged outbound ☐ Lab hold
QC pass ☐ Yes

10. Quality Checkpoints

ID When Pass Fail action
QC-SCAN After Medit Lab intake Scans usable Return to office
QC-A Pre-print Approved design + correct resin Return to design
QC-B Post-print Complete geometry Remake print
QC-C Post-wash Clean + dry Re-wash/dry
QC-D Post-cure Fully cured; supports clean Remake / salvage
QC-E Before outbound / hold Finish + clean + bag or documented lab-hold + SEAZONA Hold release

11. Remake Criteria

Finding Action
Failed scan QC Do not manufacture — request new scans
Incomplete print / critical voids / delamination Remake print
Printed on non–Pro 2 Remake on Pro 2
Wrong resin for purpose / wrong NanoCure profile Hold; correct or remake
Light support nubs only Salvage — finish and re-check QC-E
Unsure Stop and escalate to Doctor / lab lead

12. Competency

Requirement Sign-off
Read SOP-LAB-110 Tech _ Date ___
Demonstrates Die & Model 2 and Study Model White 2 paths Trainer _ Date ___
Completes 3 observed cases to bagged outbound or documented hold 1. __ 2. _ 3. ___
Trainer attests ready Trainer _ Date ___
Lab lead authorizes unsupervised production _ Date ___

13. Troubleshooting & Escalation

Problem Action
Bad scans QC-SCAN fail → return to office
Print failure Remake; filter resin; verify material assignment
Soft after cure Confirm dry part and exact Die & Model 2 or Study Model White 2 profile
Wrong model resin for thermoform vs study Confirm Rx; remake if needed

SprintRay Support: 1-800-914-8004.

14. References


Smile Avenue Family Dentistry — In-House Laboratory · Internal use only
SOP-LAB-110 DRAFT FOR REVIEW · Target effective 09/10/2026 · Supersedes prior draft revisions
Review annually or when SprintRay IFU / equipment changes. Confirm all VERIFY items before training use.