DRAFT FOR REVIEW — Not Doctor-approved for training. VERIFY items must be cleared before competency use.
Digital Temp Lab Manufacturing — Quick Card
Digital Temp · Medit Lab → bagged outbound
Smile Avenue Family Dentistry — In-House Laboratory
Station Job Aid · DRAFT FOR REVIEW · Post at printer / wash / cure bench
Pairs with SOP-LAB-050
Stack: Medit Lab → scan QC → design (VERIFY) → RayWare → Pro 2 → ProWash S → NanoCure (Digital Temp) → bag · SEAZONA
Before you start
- Case open in Medit Lab · PPE on
- Digital Temp shade per Rx in date (Bleach / A1 / A2 / B1)
- Pro 2 · ProWash S · NanoCure Digital Temp profile · IPA ≥ 91%
- SEAZONA case log ready
Stop if: failed scan QC · not on Pro 2 · design not approved · thickness < 0.6 mm · expired resin · wet before cure · wrong NanoCure profile · QC fail without remake plan · not bagged/logged
Run
- Receive in Medit Lab → verify ID/Rx (teeth, shade)
- QC-SCAN (pass or return to office)
- Design (VERIFY path): import → design/receive STL → Lab Tech approve (QC-A ≥ 0.6 mm)
- RayWare nest: Digital Temp · intaglio away · ~10° · default supports → Pro 2
- Shake 1 min → assign material/shade → print → log lot → lid unlock → QC-B
- ProWash S 3/3/3 (IPA ≥ 91%) → fully dry → QC-C
- NanoCure Digital Temp profile → remove supports → QC-D
- Smooth (Scotch-Brite) → polish pumice/compound → soap + toothbrush + water / steamer → dry
- Bag + label → SEAZONA bagged / ready for outbound → QC-E
End. Office receive / chairside disinfect / cementation are not part of this card.
QC: SCAN · A design · B print · C dry · D cure · E finish + clean + bag + SEAZONA
Remake: delamination / wrong printer / under-cured → remake · light nubs → salvage · unsure → stop